News

How to deal with the failure of the air shower room

Industrial modular Clean Room time:2021/07/21 10:56:22 click:505

Air shower room definition: also known as the air shower, it is a kind of local purification equipment with strong versatility, which is used to remove the dust adsorbed on the surface of people or objects when people or goods enter the clean area by the fan through the air shower nozzle ejected by the clean wind with high efficiency filtration. So when the air shower room failure, how to deal with it?

How to deal with the failure of the air shower room

Power switch failure. Usually there are four places in the air shower can cut off the power supply: 1, the power switch of the outdoor box of the air shower; 2, air shower indoor box control panel; 3. On both sides of the outer box of the air shower room (here the power switch can prevent the power supply from being cut off in case of emergency and effectively improve the personal safety of the staff). When the power indicator light is blocked, do not prevent a re-check of the above four air shower power supply.


The fan in the air shower room fails when it is not working. When the air shower room does not work, the first time to check whether the emergency switch of the air shower outdoor box is cut off, such as to determine the cut off, with a hand gently press, rotate to the right to let go.


Air shower room fan reverse or air shower room wind speed is very hour fault, please be sure to check whether the 380V three-phase four-wire line is reverse connection, general air shower manufacturer factory installation will have a special electrician to connect the line; Such as the opposite of the air shower line source, light will lead to the air shower fan does not work or reverse the wind speed of the air shower is reduced, the heavy will burn the whole circuit board of the air shower; It is recommended that the use of air shower enterprises do not light to replace the wiring, because of the production need to determine to move, please consult the air shower manufacturer to solve.


The air shower is not blowing, in addition to the above three points, but also need to check whether the emergency stop button inside the air shower box is pressed, such as the emergency stop button for the color, the air shower will not be blowing; If you want to press the emergency stop button again, it can work normally.


The air shower room can not automatically induction blowing fault, please check the air shower room at the lower right corner of the light sensing system, see whether the light sensing device is installed correctly, such as the light sensing both sides are relative and the light sensing is normal, it can automatically induction blowing.

When the wind speed is very low for a period of time, please check whether the primary and high efficiency filters of the air shower accumulate too much dust, if so, please replace the filter. (the initial effect filter of the air shower chamber is generally replaced once within 1-6 months, and the high efficiency filter of the air shower chamber is generally replaced once within 6-12 months).